Portable fire protection
Extinguishers, foam applicators and spare charges.
- Inspection, refilling and hydrostatic testing
- Replacement parts and equipment renewal
SOLAS Chapter II-2 Regulation 14 requires fire-fighting systems and appliances to be maintained ready for use and inspected at the intervals set out in MSC.1/Circ.1432, Revised guidelines for the maintenance and inspection of fire protection systems and appliances, as amended by MSC.1/Circ.1516. Fixed CO2 systems follow MSC.1/Circ.1318 and foam concentrates MSC.1/Circ.1312. Port state control inspectors check the service dates on every extinguisher tag and the fixed-system inspection certificate. A missed date is a deficiency; an expired 10-yearly cylinder test is a detention risk.

A concise view of the equipment we service. Your quotation confirms the work required for your vessel.
Extinguishers, foam applicators and spare charges.
BA, EEBD, breathing-air compressors and medical oxygen sets.
CO₂, foam, dry powder, water mist, sprinklers and other gas systems.
Galley CO₂, deep-fat fryer and wet-chemical systems.
Fire detection and the supporting equipment on board.








Our own teams in Türkiye and Europe coordinate your vessel’s service and supply requirements. Choose a country to see the port directory and local coordination details.
Calling in the United States? New York & New Jersey service enquiries are coordinated through our authorised partner network.
Annual inspection under MSC.1/Circ.1432, with a hydrostatic test of the body at the interval set by the maker, generally every 10 years. We do both in one visit.
Cylinder contents are checked at least every 2 to 2.5 years, the system has a 5-yearly detailed inspection, and cylinders are hydrostatically tested and refilled at 10 years, per MSC.1/Circ.1318.
Yes. Our European team carries mobile refilling and hydrostatic test equipment, so most extinguisher work is completed on board without landing the units.
Yes. We supply and analyse PFOS and PFAS-free foam concentrates and can discharge, clean and refill foam tanks in the same attendance.

Annual thorough examination, overhaul and release gear.
More →
Five-yearly dynamic tests with certified water bags.
More →
Approved liferaft station, HRU, lifejackets, loose LSA.
More →
Gas detectors, ODME, OWS, UTI, gauges, thermometers.
More →
Foam, dry powder, sprinkler water, breathing air, potable water.
More →
Annual radio survey, VDR APT, EPIRB, SART, SSAS.
More →
IMPA coded supply from our own warehouses.
More →Tell us where you are heading. We will take it from there.
FINN / OZ MARITIME