Governing requirementSOLAS XI-1 Reg. 7  ·  SOLAS VI Reg. 3  ·  MARPOL Annex I Reg. 31  ·  IMO Res. MEPC.108(49)
The obligation

Why it is required

SOLAS XI-1 Regulation 7 requires every ship to carry an appropriate portable atmosphere testing instrument for enclosed spaces, and SOLAS VI Regulation 3 requires instruments for the cargo atmosphere. MARPOL Annex I Regulation 31 and IMO Resolution MEPC.108(49) govern the oil discharge monitoring equipment on tankers. None of it means anything if the instrument reads low, which is why calibration is what turns a reading into evidence.

Finn, the OZ Maritime mascot, working with measuring instruments at a calibration bench.
Finn on dutyOZ
Scope of work

Complete coverage.
Clearly defined.

A concise view of the equipment we service. Your quotation confirms the work required for your vessel.

Gas detection

Portable and fixed detectors, tank scopes and oxygen analysers.

  • Instrument inspection and calibration
  • Reference-gas checks and calibration results

Tank & pollution monitoring

UTI, tank gauging, VECS, ODME, OWS and OMD.

  • Inspection and calibration of monitoring systems
  • Adjustment and associated instrument support

Measurement instruments

Pressure, temperature, force and alcohol measurement.

  • Gauges, thermometers, calibrators and dynamometers
  • Inspection, calibration and replacement parts
How we prove competence

Why us

  • Traceable reference gases and instruments, with the traceability stated on every certificate
  • Our own calibration bench, so instruments can be brought ashore where the work needs it
  • Attendance on board so instruments do not have to leave the vessel
  • Certificates state the reference gas, the deviation found before adjustment and the result after
Deliverables

What you receive

  • Calibration certificate per instrument, with serial number and next due date
  • As-found and as-left readings
  • Traceability reference for the standard used
  • Service date records for your fleet planning
From our work

Calibration in the field

OUR SERVICE REGIONS

Türkiye. Europe.
One point of contact.

Our own teams in Türkiye and Europe coordinate your vessel’s service and supply requirements. Choose a country to see the port directory and local coordination details.

Calling in the United States? New York & New Jersey service enquiries are coordinated through our authorised partner network.

Questions

Frequently asked

Is a bump test the same as a calibration?

No. A bump test confirms the sensor responds; a calibration adjusts the reading against a known reference gas and records the deviation. Port state control asks for the calibration record.

Can you calibrate on board?

Yes, for portable detectors, fixed systems, UTI tapes and pressure instruments. ODME work is done on board as well.

How often should a portable gas detector be calibrated?

At the maker's stated interval, normally every 6 or 12 months, with a bump test before each use. We confirm against the model.

Do you supply calibration gas?

Yes, in the mixtures the instruments on board require, delivered with the service attendance.

LET’S PLAN YOUR NEXT PORT CALL

Your vessel. Our commitment.

Tell us where you are heading. We will take it from there.

Talk to our team

Your enquiry is ready to review.

Nothing has been sent. Open your email app or copy these details and send them to service@ozmaritime.com. Attach supporting documents in your email.

Open email app

OZ MARITIME

Privacy preferences

Choose whether this website may load external maps. Your choice does not affect the service pages or port directory.

Essential preferences

Always active

Local browser storage remembers your choice for up to 180 days. If storage is unavailable, it applies to this page only.

Allow map images to load from OpenStreetMap. The provider receives your IP address and map requests. Switching this off removes loaded maps and stops further map-image requests.

No analytics or advertising trackers are installed, so there are no settings for those categories.

Read our cookie and storage policy